APPLICATION
SOLUTION
These sensors use ENVEA ElectroDynamic™ Technology which is unaffected by probe contamination or changes in velocity and after correlation with an Isokinetic sample, can be calibrated to output a mg/m³ reading.
The system was installed after a supercharged fluidized bed incinerator where flue gas temperatures after the dust collector reach 300-550°C. The VIEW 370 & Leak Alert 65-02 have high temperature options up to 800°C & 400°C respectively and are designed for high quality emission measurement in industrial stacks after various types of filters and driers.
ENVEA ElectroDynamic™ sensors have simple, one-sided stack installation and the “Broken bag mode” enables the early detection and location of leaking or broken filter bags from bag filters. This advanced diagnostic mode enables better operation of bagfilters and lower running costs for the plant operator.
When used with Dust Tools software, the system can also monitor each chamber of multi-chamber bag filters and identify predictive bag leakages and locations of leaking bag rows in single-chamber or multi-row bag filters.
How key requirements were met
Prompt domestic technical support will be handled by Kansai Automation, ENVEA’s local partner of more than 25 years that specializes in the sales and manufacturing of Level Sensor and Environmental Instruments.